Solution — commercial
Server rack: protecting servers and network gear
Power supplies, UPS units, loaded power strips: a server rack concentrates heat. The StickerProMaxx puts out a fire in the closed rack with a non-conductive agent that leaves less than 1 g of residue.
- Non-conductive agent
- Residue under 1 g, non-toxic
- No piping in the room
- From 125 to 1,000 liters

170 °C
activation threshold
0
pressure, wiring or maintenance
5 years
warranty and service life
30 s
to install
The risk
Concentrated equipment heat
A closed 42U rack is often 600 to 1,000 liters. Hot spots come from power supply units, built-in UPS units and power strips. A generator at the top, cable above the equipment, protects the whole rack.
Ventilated rack: effectiveness requires a closed enclosure (0 to 2% opening). A rack with perforated doors is not a closed volume.

Which model?
Depending on the rack volume
| Model | Capacity | Detection | Max. volume | Max. mounting height | Price incl. VAT | |
|---|---|---|---|---|---|---|
| StickerProMaxx 250 | enclosure ≤ 650 × 1,100 mm | 50 cm | 250 L | 110 cm | Coming soon | Buy |
| StickerProMaxx 500 | enclosure ≤ 800 × 1,900 mm | 50 cm | 500 L | 190 cm | Coming soon | Buy |
| StickerProMaxx 750 | enclosure ≤ 1,100 × 1,900 mm | 50 cm | 750 L | 190 cm | Coming soon | Buy |
| StickerProMaxx 1000 | enclosure ≤ 1,200 × 1,900 mm | 50 cm | 1,000 L | 190 cm | Coming soon | Buy |
Example: rack with inside dimensions of 600 × 1,800 × 800 mm = 864 liters → StickerProMaxx 1000 (enclosure up to 1,200 × 1,900 mm). Up to 2,100 mm high, the rack is sized on its actual volume; beyond that, a buffer zone is created at the bottom (see the calculator).
Installation
Positioning the generator correctly
- Lock out the cabinet (isolation and lockout) according to site rules.
- Measure the inside volume (width × height × depth) and check that the enclosure is closed (0 to 2% ventilation).
- Mount it at the top, diffuser facing down, above the hazard, at the maximum height allowed for the model (90 to 190 cm).
- Lay out the heat-sensitive cable above the most heavily loaded equipment (power supplies, UPS).
- Return to service and record the installation date in the safety log.
Frequently asked questions
Does the aerosol damage servers?
The agent is non-conductive and leaves less than 1 g of residue that can be cleaned dry. After an activation, have the equipment checked before returning it to service.
Should the power be cut when it activates?
The remote signaling option can trigger a power cutoff and report the generator’s status.
Does the system contain pressurized gas?
No, none: no pressure to check, no risk of leaks.
Accessories
Accessories for server racks
Activation signaling to the monitoring system and detection extension above the equipment.

AX-REPORT signaling kit
Dry contact and 3 Ω resistor: power cutoff or status reporting to a control panel, BMS or PLC.
Coming soon

AX-DETECT-ML detection cable
Extension sold by the meter to cover a wider row or detect on every row.
Coming soon

AX-SERIE connector
Copper crimp connector: joins an extension or links several generators in series.
Coming soon
Size your rack
Enter the inside dimensions of the rack: the guide suggests the model.