Solution — commercial

Server rack: protecting servers and network gear

Power supplies, UPS units, loaded power strips: a server rack concentrates heat. The StickerProMaxx puts out a fire in the closed rack with a non-conductive agent that leaves less than 1 g of residue.

  • Non-conductive agent
  • Residue under 1 g, non-toxic
  • No piping in the room
  • From 125 to 1,000 liters
StickerProMaxx Pro range: generator installed at the top of a commercial electrical enclosure

170 °C

activation threshold

0

pressure, wiring or maintenance

5 years

warranty and service life

30 s

to install

The risk

Concentrated equipment heat

A closed 42U rack is often 600 to 1,000 liters. Hot spots come from power supply units, built-in UPS units and power strips. A generator at the top, cable above the equipment, protects the whole rack.

Ventilated rack: effectiveness requires a closed enclosure (0 to 2% opening). A rack with perforated doors is not a closed volume.

Remote activation signaling: audible alarm, power cutoff and status reporting

Which model?

Depending on the rack volume

ModelCapacityDetectionMax. volumeMax. mounting heightPrice incl. VAT
StickerProMaxx 250enclosure ≤ 650 × 1,100 mm50 cm250 L110 cmComing soonBuy
StickerProMaxx 500enclosure ≤ 800 × 1,900 mm50 cm500 L190 cmComing soonBuy
StickerProMaxx 750enclosure ≤ 1,100 × 1,900 mm50 cm750 L190 cmComing soonBuy
StickerProMaxx 1000enclosure ≤ 1,200 × 1,900 mm50 cm1,000 L190 cmComing soonBuy

Example: rack with inside dimensions of 600 × 1,800 × 800 mm = 864 liters → StickerProMaxx 1000 (enclosure up to 1,200 × 1,900 mm). Up to 2,100 mm high, the rack is sized on its actual volume; beyond that, a buffer zone is created at the bottom (see the calculator).

Installation

Positioning the generator correctly

  1. Lock out the cabinet (isolation and lockout) according to site rules.
  2. Measure the inside volume (width × height × depth) and check that the enclosure is closed (0 to 2% ventilation).
  3. Mount it at the top, diffuser facing down, above the hazard, at the maximum height allowed for the model (90 to 190 cm).
  4. Lay out the heat-sensitive cable above the most heavily loaded equipment (power supplies, UPS).
  5. Return to service and record the installation date in the safety log.

Frequently asked questions

Does the aerosol damage servers?

The agent is non-conductive and leaves less than 1 g of residue that can be cleaned dry. After an activation, have the equipment checked before returning it to service.

Should the power be cut when it activates?

The remote signaling option can trigger a power cutoff and report the generator’s status.

Does the system contain pressurized gas?

No, none: no pressure to check, no risk of leaks.

Accessories

Accessories for server racks

Activation signaling to the monitoring system and detection extension above the equipment.

StickerProMaxx AX-REPORT signaling kit: dry contact cable for power cutoff or status reporting

AX-REPORT signaling kit

Dry contact and 3 Ω resistor: power cutoff or status reporting to a control panel, BMS or PLC.

Coming soon

AX-DETECT-ML heat-sensitive detection cable on a reel, sold by the meter, for StickerProMaxx automatic extinguishers

AX-DETECT-ML detection cable

Extension sold by the meter to cover a wider row or detect on every row.

Coming soon

AX-SERIE copper crimp connector for linking StickerProMaxx generators in series

AX-SERIE connector

Copper crimp connector: joins an extension or links several generators in series.

Coming soon

Size your rack

Enter the inside dimensions of the rack: the guide suggests the model.