Solution — industry

Automation cabinet: protecting production

PLCs, variable speed drives, switch-mode power supplies: a fire in a control cabinet stops the line. The StickerProMaxx puts it out inside the cabinet, with no piping and no maintenance.

  • Vibration-resistant (8 G)
  • Up to 98% humidity
  • Series mounting for compartmentalized cabinets
  • Remote signaling option
Industrial electrical cabinet protected by StickerProMaxx with a detection cable on each row

170 °C

activation threshold

0

pressure, wiring or maintenance

5 years

warranty and service life

30 s

to install

The risk

Drives and power supplies: heat sources

Drives dissipate a lot of heat and control cabinets are often packed. The detection cable, laid above each row of equipment, reacts right where the fire starts.

Two StickerProMaxx generators mounted in series in a large industrial cabinet

Which model?

Depending on the cabinet volume

ModelCapacityDetectionMax. volumeMax. mounting heightPrice incl. VAT
StickerProMaxx 125enclosure ≤ 600 × 900 mm50 cm125 L90 cmComing soonBuy
StickerProMaxx 250enclosure ≤ 650 × 1,100 mm50 cm250 L110 cmComing soonBuy
StickerProMaxx 500enclosure ≤ 800 × 1,900 mm50 cm500 L190 cmComing soonBuy
StickerProMaxx 750enclosure ≤ 1,100 × 1,900 mm50 cm750 L190 cmComing soonBuy
StickerProMaxx 1000enclosure ≤ 1,200 × 1,900 mm50 cm1,000 L190 cmComing soonBuy

For a 1,800 × 1,200 × 400 mm cabinet (864 liters): one StickerProMaxx 1000, or two generators in series if the cabinet is compartmentalized.

Installation

Positioning the generator correctly

  1. Lock out the cabinet (isolation and lockout) according to site rules.
  2. Measure the inside volume (width × height × depth) and check that the enclosure is closed (0 to 2% ventilation).
  3. Mount it at the top, diffuser facing down, above the hazard, at the maximum height allowed for the model (90 to 190 cm).
  4. Lay out the heat-sensitive cable above each row, especially above the drives.
  5. Return to service and record the installation date in the safety log.

Frequently asked questions

Is the aerosol compatible with electronic equipment?

Yes: the agent is non-conductive and leaves less than 1 g of residue that can be cleaned dry. Have the equipment checked before returning it to service after an activation.

Can it be integrated with the monitoring system?

Yes, with the remote signaling option (status reporting contact).

Who can install it?

An electrician or the maintenance team, following the instructions; no wiring is needed to the generator itself.

Accessories

Accessories for automation cabinets

Signaling to the PLC or BMS, detection extension and series mounting.

StickerProMaxx AX-REPORT signaling kit: dry contact cable for power cutoff or status reporting

AX-REPORT signaling kit

Dry contact and 3 Ω resistor: power cutoff or status reporting to a control panel, BMS or PLC.

Coming soon

AX-DETECT-ML heat-sensitive detection cable on a reel, sold by the meter, for StickerProMaxx automatic extinguishers

AX-DETECT-ML detection cable

Extension sold by the meter to cover a wider row or detect on every row.

Coming soon

AX-SERIE copper crimp connector for linking StickerProMaxx generators in series

AX-SERIE connector

Copper crimp connector: joins an extension or links several generators in series.

Coming soon

Size your cabinet

Inside volume, height and width: the guide suggests the model or combination.