Pro range
StickerProMaxx 125: the automatic extinguisher for commercial enclosures up to 125 liters
For commercial electrical enclosures and small cabinets, it protects up to 125 liters, keeps constant watch and puts out a fire on its own, with no power, no pressure and no maintenance.
- Enclosure or small cabinet up to 125 liters
- 50 cm (20 in) of heat-sensitive cable
- Mounts up to 90 cm from the bottom, series mounting possible

170 °C
activation threshold
50 cm
detection
125 L
protected volume
5 years
warranty

Commercial electrical enclosure
The generator mounts at the top of the enclosure, its 50 cm cable above the equipment.
Which enclosure is it for?
Commercial enclosures
Offices, stores, utility rooms: electrical enclosures there run day and night, often in empty rooms. The StickerProMaxx 125 protects a volume of up to 125 liters, for example a 50 × 50 × 50 cm enclosure.
Is it the right model?
Is the 125 right for your cabinet?
The golden rule: the detection cable must cover the hazard zone, and the enclosure volume must not exceed the generator’s capacity. Choose detection first, volume second.
The StickerProMaxx 125 is right if…
| Enclosure volume | 125 liters maximum (for example 50 × 50 × 50 cm) |
| Mounting height | 90 cm (35 in) max. from the bottom of the enclosure |
| Detection | 50 cm of heat-sensitive cable, placed above the most exposed area |
| Ventilation | 0 to 2%; beyond that, increase the capacity |
| Large volumes | several generators mounted in series |

How it works
It detects, it activates, it extinguishes
- Detection. The heat-sensitive cable (50 cm) reacts on contact with the flame, at 170 °C ± 10 °C.
- Activation. Within 2 to 4 seconds, with no electricity and no human intervention.
- Extinguishing. A condensed aerosol of potassium and strontium particles fills the enclosure and stops combustion within 10 to 20 s.
No pressurized cylinder, no piping, no battery: the generator stays inert until the day it is needed.
Installation
30 seconds to install, no wiring
Electrical safety. Switch off the power before any work. The supply side of the main breaker, solar panels and batteries may remain live. If in doubt, call an electrician.
- Switch off the power at the breaker or main disconnect.
- Open the enclosure : remove the front panel or cover, or open the door.
- Clean the mounting surface, preferably with isopropyl alcohol.
- Mount it on the ceiling of the enclosure, diffuser facing down, directly above the area to protect, no more than 90 cm from the bottom. Press for 3 to 4 seconds (or fix with two screws).
- Lay out the 50 cm cable above the most exposed area (terminal blocks, breakers, drives), without tight bends, and check that nothing blocks the diffuser.
- Close up, switch the power back on and write the installation date on the warranty label.

Ceiling mounting only, directly above the area to protect. Avoid any direct heat source.
Why condensed aerosol
Protection you install and forget
No pressure, no maintenance
No hydrostatic testing, no refills: 6-year service life, replace after 5 years.
Made for electrical fires
Non-conductive aerosol, effective on class E (electrical) fires, residue under 1 g, non-corrosive and non-toxic.
Compact and eco-friendly
100 mm long and 26.6 g, 100% recyclable housing, zero impact on the ozone layer and climate (ODP 0, GWP 0).
Pro and Industrial ranges
Compare models
Choose the model based on the inside volume of the enclosure. Beyond 1,000 liters, several generators are mounted in series.
| Model | Volume | Detection | Discharge | Max. mounting height |
|---|---|---|---|---|
| StickerProMaxx 125 | 125 L | 50 cm | 10–20 s | 90 cm |
| StickerProMaxx 250 | 250 L | 50 cm | 12–22 s | 110 cm |
| StickerProMaxx 500 | 500 L | 50 cm | 16–26 s | 190 cm |
| StickerProMaxx 750 | 750 L | 50 cm | 20–30 s | 190 cm |
| StickerProMaxx 1000 | 1,000 L | 50 cm | 22–32 s | 190 cm |

Compliance and documents
EU type-examination passed, patented, designed and assembled in France
Aerosol generator, category P1 pyrotechnic firefighting device under Directive 2013/29/EU. EU type-examination (Module B) passed with notified body No. 0163 (LOM). Composition protected by a European patent. Designed and assembled in Toulouges, France. Transport: UN 3178, class 4.1, packing group III.

Frequently asked questions
Your questions about the StickerProMaxx 125
Who can install it?
The StickerProMaxx 125 mounts with no electrical wiring, but work inside an electrical cabinet must be done by a qualified person. Our support team can help you size the installation: support@stickerpromaxx.com.
My cabinet is larger than this model’s volume: what should I do?
Choose the next model up, or mount several generators in series. Our support team can carry out a feasibility study: support@stickerpromaxx.com.
Does it need maintenance?
No: it is unpressurized and maintenance-free. A simple monthly visual check is enough (housing secure, diffuser clear, detection cable intact), and you replace it after 5 years.
What happens when it activates?
The flame triggers the detection cable at 170 °C: within 2 to 4 seconds, the generator releases a condensed aerosol that puts out the fire inside the enclosure within 10 to 20 s. Then: wait, switch off the power, air out the room, clean the residue (under 1 g, non-corrosive) and replace the device.
Does the aerosol damage electrical equipment?
No. The aerosol is non-conductive and its residue is minimal and non-corrosive: it tackles an electrical (class E) fire without damaging nearby equipment.
Does it replace a fire extinguisher?
No. It automatically protects the inside of a closed enclosure. It doesn’t replace a portable extinguisher for a fire that has spread to the room, or a fire safety system where one is required.
Protect your cabinet today
Ships within 2 business days from Toulouges, France · delivery to France, the European Union, Switzerland, Norway and the United Kingdom · 5-year warranty.