Solution — homes and small premises
Junction boxes: the fire nobody sees
Attics, drop ceilings, walls, garage, basement: your junction boxes are closed, hidden and far from any detector. A StickerProMaxx slipped inside detects the heat and automatically puts out a fire before it gets out of the box.

20 to 35%
of home fires are electrical in origin
82.6%
of installations over 15 years old have at least one defect
Coming soon
to protect a junction box
Sources: French National Electrical Safety Observatory (ONSE).
The weak spot
Why a junction box can catch fire
Every junction box concentrates hand-made connections: terminal strips, push-in connectors, twisted wires. Over time, heating and cooling cycles loosen the contacts. A loose contact heats up, blackens the insulation and can cause an electrical arc.
The danger comes mainly from the location: the box is closed, recessed or high up, often in a room nobody goes into and with no smoke detector. By the time the fire is visible, it has already reached the insulation, the framing or the drop ceiling.
Warning signs: a smell of hot plastic, black marks around a box, flickering lights or a breaker tripping for no reason. Have the installation checked by an electrician.
Where to find them
Where are your junction boxes?
Attics and lofts
Lighting, outlets and ventilation often run through boxes sitting on the insulation, where a fire stays invisible the longest.
Drop ceilings and walls
Recessed lights and room circuits are connected in boxes hidden above the drywall.
Basement, crawl space and garage
Humidity, dust and temperature swings wear out connections faster than elsewhere.
Outdoors
Garden lighting, gate, pump: inside a closed weatherproof box, the generator is protected from water and works from -30 °C to +70 °C.
Offices and stores
The drop ceilings of small commercial premises also hide many junction boxes.
Small subpanel enclosures
A subpanel of a few modules in the garage, the workshop or upstairs is protected with the same logic.

How it works
Automatic extinguishing, inside the box
The generator mounts inside the box and its detection cable runs horizontally above the connections.
- Detection: the heat-sensitive cable reacts at 170 °C, as close as possible to the hot spot.
- Activation: the generator triggers automatically within 2 to 4 seconds, with no electricity and no intervention.
- Extinguishing: the condensed aerosol fills the closed box and smothers the fire before it can escape.
Which model?
Measure the inside width of your box
The detection cable must cover the full width above the connections. So it’s the inside width of the box that determines the model.
| Model | Inside width of the box | Detection | Max. volume | Price incl. VAT (single / pack of 2) | |
|---|---|---|---|---|---|
| StickerProMaxx 04 | 67 to 129 mm — standard junction box | built-in loop · 5 cm | 30 L | Coming soon | Buy |
| StickerProMaxx 08 | 130 to 229 mm — large box, enclosure up to 8 modules | 13 cm | 30 L | Coming soon | Buy |
| StickerProMaxx 12 | 230 to 329 mm — subpanel enclosure up to 12 modules | 23 cm | 30 L | Coming soon | Buy |
| StickerProMaxx 18 | 330 mm and up — subpanel enclosure up to 18 modules | 33 cm | 30 L | Coming soon | Buy |
Less than 67 mm wide? The box is too small to hold a generator. Replace it with a larger box during a renovation.
Several boxes? One generator per box. Packs of 2 lower the price of each protection.
Installation
Install in 5 minutes
- Switch off the power at the breaker for the circuit concerned, then open the box lid.
- Measure the inside width to check the chosen model.
- Clean the mounting surface with isopropyl alcohol.
- Mount the generator in the box, preferably near the top, with the double-sided adhesive pressed for 3 to 4 seconds or two screws.
- Run the detection cable horizontally above the connections, across the full width, without bending it or pinching it against a terminal.
- Close the box and switch the power back on. No adjustments, no maintenance.
Why StickerProMaxx
Protection made for forgotten places
- No pressure, no maintenance: nothing to check for 5 years.
- 5-year warranty and EU type-examination passed under Directive 2013/29/EU.
- Non-conductive: safe to use on live wires.
- Approved for sealed boxes: once the IP55 box is closed, it’s also suitable for the garage and outdoors.
- Minimal, non-toxic residue: less than one gram, no greenhouse gases.
- Compact: 67 mm for the StickerProMaxx 04, it slips into a standard box.
Frequently asked questions
Does it replace a breaker or a smoke detector?
No. The breaker cuts the power in case of overload or short circuit, the detector alerts you, and StickerProMaxx puts out the fire where it starts. They’re three complementary protections.
What’s the minimum box size?
67 mm inside width for the StickerProMaxx 04. From 130 mm, move up to the StickerProMaxx 08, whose detection cable covers the full width.
Can it be installed in a sealed box in the garage or outdoors?
Yes. The generator is designed for indoor use (IP20), but once installed in a closed IP55 box, it’s protected from water and dust. It works from -30 °C to +70 °C.
Do I need an electrician to install it?
Installation requires no wiring: you mount the generator and position the cable. It’s done with the power off. If you’re not comfortable opening an electrical box, have an electrician do it.
What should I do after an activation?
Wait a few minutes, switch off the power, air out, clean the light deposit, then have the connections checked before replacing the generator. Full details: After an activation.
How long does it stay effective?
It needs no maintenance. We recommend replacing it after 5 years, the period covered by the warranty.