Residential range
StickerProMaxx 12: the automatic extinguisher for panels with 12 modules per row
Stuck to the ceiling of a panel or enclosure with 12 modules per row, it keeps constant watch and puts out a fire on its own within seconds, with no power, no pressure and no maintenance.
- Garage, workshop or outbuilding subpanel
- Up to 12 modules per row, 30 liters, up to 4 rows
- 23 cm (9 in) of detection cable, installs in 30 seconds

170 °C
activation threshold
23 cm
detection
30 L
protected volume
5 years
warranty
Which enclosure is it for?
The subpanel: the one everyone forgets
Garage, workshop, outbuilding, EV charger enclosure: these subpanels power heavy-duty appliances and often stay out of sight. The StickerProMaxx 12 covers a 12-module row with its 23 cm of detection cable.

Garage panel
A panel with 2 rows of 12 modules: choose the model based on the fullest row.

Garage and EV charger
Garage enclosure and the protection box for the electric vehicle charger.
Is it the right model?
Is the 12 right for your panel?
The golden rule: the detection cable must cover the hazard zone, and the enclosure volume must not exceed the generator’s capacity. Choose detection first, volume second.
Example: a 30 cm wide PVC enclosure cannot be effectively protected by the 12: move up to the StickerProMaxx 18.
The StickerProMaxx 12 is right if…
| Enclosure | 12 modules per row, up to 4 rows (choose based on the fullest row) |
| Enclosure volume | 30 liters maximum |
| Mounting height | 65 cm (25.6 in) max. from the bottom of the enclosure |
| Detection | 23 cm of detection cable |
| Enclosure ventilation | 0 to 2% (closed enclosure) |

How it works
It detects, it activates, it extinguishes
- Detection. The heat-sensitive cable (23 cm) reacts on contact with the flame, at 170 °C ± 10 °C.
- Activation. Within 2 to 4 seconds, with no electricity and no human intervention.
- Extinguishing. A condensed aerosol of potassium and strontium particles fills the enclosure and stops combustion within 2 to 4 s.
No pressurized cylinder, no piping, no battery: the generator stays inert until the day it is needed.
Installation
30 seconds to install, no wiring
Electrical safety. Switch off the power before any work. The supply side of the main breaker, solar panels and batteries may remain live. If in doubt, call an electrician.
- Switch off the power at the breaker or main disconnect.
- Open the enclosure : remove the front panel or cover, or open the door.
- Clean the mounting surface, preferably with isopropyl alcohol.
- Mount it on the ceiling of the enclosure, diffuser facing down, directly above the area to protect, no more than 65 cm from the bottom. Press for 3 to 4 seconds (or fix with two screws).
- Lay out the detection cable (23 cm) above the entire fullest row, without tight bends, and check that nothing blocks the diffuser.
- Close up, switch the power back on and write the installation date on the warranty label.

Ceiling mounting only, directly above the area to protect. Avoid any direct heat source.
Why condensed aerosol
Protection you install and forget
No pressure, no maintenance
No hydrostatic testing, no refills: 6-year service life, replace after 5 years.
Made for electrical fires
Non-conductive aerosol, effective on class E (electrical) fires, residue under 1 g, non-corrosive and non-toxic.
Compact and eco-friendly
120 mm long and 21.8 g, 100% recyclable housing, zero impact on the ozone layer and climate (ODP 0, GWP 0).
Residential range
Compare models
The wider the enclosure, the wider the detection must be: choose the detection width first, then the volume.
| Model | Modules | Detection | Volume | Max. mounting height |
|---|---|---|---|---|
| StickerProMaxx 04 | 4 (1 row) | built-in loop · 5 cm | 30 L | 20 cm |
| StickerProMaxx 08 | 8 per row | 13 cm | 30 L | 65 cm |
| StickerProMaxx 12 | 12 per row | 23 cm | 30 L | 65 cm |
| StickerProMaxx 18 | 18 per row | 33 cm | 30 L | 65 cm |
| StickerProMaxx 50Mx | 4 rows of 13 | 135 cm | 50 L | 65 cm |

Compliance and documents
EU type-examination passed, patented, designed and assembled in France
Aerosol generator, category P1 pyrotechnic firefighting device under Directive 2013/29/EU. EU type-examination (Module B) passed with notified body No. 0163 (LOM). Composition protected by a European patent. Designed and assembled in Toulouges, France.

Frequently asked questions
Your questions about the StickerProMaxx 12
Can I install it myself?
Yes. The StickerProMaxx 12 mounts inside the panel in 30 seconds, with no electrical wiring at all. Switch off the power before opening the panel; if in doubt, call an electrician.
My panel has rows of 13 modules: is the 12 enough?
No. The 23 cm cable covers 12 modules; for a row of 13 to 18 modules, choose the StickerProMaxx 18 and its 33 cm of detection.
Does it need maintenance?
No: it is unpressurized and maintenance-free. A simple monthly visual check is enough (housing secure, diffuser clear, detection cable intact), and you replace it after 5 years.
What happens when it activates?
The flame triggers the detection cable at 170 °C: within 2 to 4 seconds, the generator releases a condensed aerosol that puts out the fire inside the enclosure within 2 to 4 s. Then: wait, switch off the power, air out the room, clean the residue (under 1 g, non-corrosive) and replace the device.
Does the aerosol damage electrical equipment?
No. The aerosol is non-conductive and its residue is minimal and non-corrosive: it tackles an electrical (class E) fire without damaging nearby equipment.
Does it replace a fire extinguisher?
No. It automatically protects the inside of a closed enclosure. It doesn’t replace a portable extinguisher for a fire that has spread to the room, or a fire safety system where one is required.
Protect your panel today
Ships within 2 business days from Toulouges, France · delivery to France, the European Union, Switzerland, Norway and the United Kingdom · 5-year warranty.