Pro range

StickerProMaxx 50Mx: full panel protection, row by row

Its 135 cm of detection cable snakes above every row: wherever the fire starts, it’s detected within 2 seconds. It’s the most complete protection for an electrical panel.

  • 135 cm of cable above every row
  • 4 rows of 13 modules, up to 50 liters
  • Early detection, discharge in 2 to 4 s
StickerProMaxx 50Mx: aerosol generator with 135 cm of serpentine detection cable

170 °C

activation threshold

135 cm

detection

50 L

protected volume

5 years

warranty

StickerProMaxx 50Mx with detection cable snaking across each row of an electrical cabinet

Cable on every row

The 135 cm of cable snakes above all 4 rows of the panel.

Which enclosure is it for?

We sell detection, not volume

With standard detection, the cable sits above the top row: a fire that starts lower down has to rise up to it. The StickerProMaxx 50Mx runs its cable above every row, so it triggers at the very first flames, wherever they appear.

Is it the right model?

Is the 50Mx right for your panel?

The golden rule: the detection cable must cover the hazard zone, and the enclosure volume must not exceed the generator’s capacity. Choose detection first, volume second.

The StickerProMaxx 50Mx is right if…

Enclosure4 rows of 13 modules, zone height up to 650 mm
Enclosure volume50 liters maximum
Mounting height65 cm (25.6 in) max. from the bottom of the enclosure
Detection135 cm of cable, 2 loops
Enclosure ventilation0 to 2% (closed enclosure)
How it works in 3 steps: heat detection, fast activation, extinguishing

How it works

It detects, it activates, it extinguishes

  • Detection. The heat-sensitive cable (135 cm) reacts on contact with the flame, at 170 °C ± 10 °C.
  • Activation. Within 2 to 4 seconds, with no electricity and no human intervention.
  • Extinguishing. A condensed aerosol of potassium and strontium particles fills the enclosure and stops combustion within 2 to 4 s.

No pressurized cylinder, no piping, no battery: the generator stays inert until the day it is needed.

Installation

30 seconds to install, no wiring

Electrical safety. Switch off the power before any work. The supply side of the main breaker, solar panels and batteries may remain live. If in doubt, call an electrician.

  1. Switch off the power at the breaker or main disconnect.
  2. Open the enclosure : remove the front panel or cover, or open the door.
  3. Clean the mounting surface, preferably with isopropyl alcohol.
  4. Mount it on the ceiling of the enclosure, diffuser facing down, directly above the area to protect, no more than 65 cm from the bottom. Press for 3 to 4 seconds (or fix with two screws).
  5. Snake the 135 cm cable above every row of breakers, without tight bends, and check that nothing blocks the diffuser.
  6. Close up, switch the power back on and write the installation date on the warranty label.
StickerProMaxx 50Mx with detection cable snaking across each row of an electrical cabinet

Ceiling mounting only, directly above the area to protect. Avoid any direct heat source.

Why condensed aerosol

Protection you install and forget

No pressure, no maintenance

No hydrostatic testing, no refills: 6-year service life, replace after 5 years.

Made for electrical fires

Non-conductive aerosol, effective on class E (electrical) fires, residue under 1 g, non-corrosive and non-toxic.

Compact and eco-friendly

120 mm long and 28.35 g, 100% recyclable housing, zero impact on the ozone layer and climate (ODP 0, GWP 0).

Pro range

Compare models

The wider the enclosure, the wider the detection must be: choose the detection width first, then the volume.

ModelModulesDetectionVolumeMax. mounting height
StickerProMaxx 044 (1 row)built-in loop · 5 cm30 L20 cm
StickerProMaxx 088 per row13 cm30 L65 cm
StickerProMaxx 1212 per row23 cm30 L65 cm
StickerProMaxx 1818 per row33 cm30 L65 cm
StickerProMaxx 50Mx4 rows of 13135 cm50 L65 cm
StickerProMaxx Pro range: 50Mx (135 cm detection, 50 L), 125 and 250 (50 cm detection, 125 and 250 liters)

Compliance and documents

EU type-examination passed, patented, designed and assembled in France

Aerosol generator, category P1 pyrotechnic firefighting device under Directive 2013/29/EU. EU type-examination (Module B) passed with notified body No. 0163 (LOM). Composition protected by a European patent. Designed and assembled in Toulouges, France.

StickerProMaxx generator EU type-examination under Directive 2013/29/EU

Frequently asked questions

Your questions about the StickerProMaxx 50Mx

Can I install it myself?

Yes. The StickerProMaxx 50Mx mounts inside the panel in 30 seconds, with no electrical wiring at all. Switch off the power before opening the panel; if in doubt, call an electrician.

Why a cable above every row?

Because a fire that starts in a lower row takes time to reach a cable placed at the top of the panel. With 135 cm of cable spread across all 4 rows, detection happens within 2 seconds, whichever row it is.

Does it need maintenance?

No: it is unpressurized and maintenance-free. A simple monthly visual check is enough (housing secure, diffuser clear, detection cable intact), and you replace it after 5 years.

What happens when it activates?

The flame triggers the detection cable at 170 °C: within 2 to 4 seconds, the generator releases a condensed aerosol that puts out the fire inside the enclosure within 2 to 4 s. Then: wait, switch off the power, air out the room, clean the residue (under 1 g, non-corrosive) and replace the device.

Does the aerosol damage electrical equipment?

No. The aerosol is non-conductive and its residue is minimal and non-corrosive: it tackles an electrical (class E) fire without damaging nearby equipment.

Does it replace a fire extinguisher?

No. It automatically protects the inside of a closed enclosure. It doesn’t replace a portable extinguisher for a fire that has spread to the room, or a fire safety system where one is required.

Protect your panel today

Ships within 2 business days from Toulouges, France · delivery to France, the European Union, Switzerland, Norway and the United Kingdom · 5-year warranty.